Product Catalog > RP248CN 8-48 Zone Control Panel
click for larger photo
RP248CN 8-48 Zone Control Panel
RP248CN 8-48 Zone Control Panel
Name︰RP248CN 8-48 Zone Control Panel
Model No.︰RP248CN
Brand Name︰ROISCOK
Country of Origin︰China
Unit Price︰USD $ 60 / pc
Minimum Order︰1 pc
Product Description
 

RP248CN 8-48 with popular LCD keypads, 8 programmable zones, and the features of network linking and alarm linkage output. It is compatible with internationally popular communication format. With chargeable circuits and clock. It has memory function, so that the programmed parameters and the information of the control panel's condition would not lose when power is cut.

The function is perfect, the programming is convenient, the installation is easy, and the usage is safe. It supports programming any address information at will. It could greatly reduce the working time of installation and programming .

RP248CN 8-48 adopts the latest technology, LSI Application, SMT jointing technology, and digital program design to ensure the reliability and stability of the system. Its appearance is compact and elegant with reasonable layout.

The distance is up to 1500M between control panel and module.

 


LCD Keypads (RP248KCL)


Display of Two Lines and 32 Characters

3 Keypad Emergency Zones: Panic[1]+[2], Fire[4]+[5], Special Emergency[7]+[8]

Menu Indicates the User Functions and the Installer Programing

Key-press with Audible Feedback

System Condition Display

Trouble Display

LED Indication: Alarm, Power, Armed, Disarmed, Bypass, Ready, Tamper

User Information is Displayed on Screen (except for password)

LCD Backlight

Tamper is Supervised

Alarm By Duress Code

Easy to Use Hot-keys for Simple Bypassing and Not-ready Zones Display

One Button for Quick Arming

One Button for Quick Perimeter Arming

Alarm Memory Display

System Trouble Display

Up to 4 LCD Keypads can be Connected

 

Mainboard(RP248MB)

Zone Terminal Resistor (2.2KΩ)

8 Zones on Mainboard

Expandable up to 48 Programmable Wired Zones or 8 Wired Zones + 40 Wireless Zones

Special Zones: Zone-5 is Fire Zone, Zone-6 is Tamper Zone

Can be Parted to 8 Divisions

11 types of Programmable Zones, 7 Types of Voice Formats

Zone Terminal: NC, NO, Single End with Resistor

Programmable Output: 70mA

Expandable to 32 Large Current Output: 3A

50 Event Records

8 Groups of 4 Gradable Codes

Switch Output: 250mA

Built-in Siren Driver: 750mA max

Built-in Digital Clock

Daily Test Report

Function of End Calling

Disarm/Arm Report

4 LCD Keypads can be Connected to Control Panel

Programmble Voice For the Siren Output

Current output:750mA(max)

Auxiliary power Output: 400mA

Mainboard has 7 types of Fire Alarm Bell Voice Driver

Connectible with Four 1.5V 12A Power Supply Expansion Board

Mainboard has One 70mA Programmable Open Circuit Collector

Connectible with 32 C-type Programmble Relays of 3A

Circuit Responding Time of Each Zone can be Set as 10ms, 500ms or 1s

The Distance is Up to 1500M Between Module and Control Panel

 

Built-in Digital Communicator

Attached Digital Communicator, Compatible with Contract ID,4+2

2 Central Station Numbers

4 Follow-me Phone Numbers

 

Code

One Installer Code

One (User) Main Code (Can Create Duress Code Automatically)

8 Gradable User Codes

 

Periodic Test

Offer Testing Report to Alarm Center Automatically

 

Peripheral Equipment

Expandable  Function of 32 lines Relay Output

Disarmed/Armed by Romote Control. Any Zone can be Programmed to be the Switch Lock Port

RS232 Port

Expandable Zone Board

 

8 Zones Expansion Module EZ8

8 Zones Wiring Expansion Module

Power Supply Output of Switch Lock

Zones Terminal: NC, NO, Single End with Resistor (2.2kΩ)

Circuit Responding Time of Each Zone can be Set as 10ms, 500ms or 1s

4-Line Connection, and Easy for Installation

 

8 Zones Wireless Expansion Module EW8

Wireless Expansion Module

Time to Supervise is Programmable

Monitoring of Emitter in Low Power

Tamper of Emitter is Supervised

Indication of Interfering Signal

Wireless Detector is Supported

Verifying code by cycle

 

4 Program Output Expansion Module E04

4 lines programmable output(3A)

Output: NC, NO, Locked or Pulse

Responding to Various Events

XTO Module Supports X-10 Agreement

 

Power Supply Output Expansion Module (RP248EPS)

Connect with 5 Modules by 4-Line

Provide 2.0A,12V Power to Other Module and Siren

Complete Supervision of Power Supply condition, including Battery, AC, Siren Circuit and Auxiliary Power Output

Built-in Siren Driver

Tamper is Supervised

Memory When Power is cut

 

Digital Voice Module RV2006V

1 Piece of Voice Message, Time Lasts 20s

Follow-me Number is Assignable

 

Timing Function

Auto Daily Arm

Auto Daily Test Report

Disarm/Arm Report at Window

 

Monitoring Function

Trouble Data can be Displayed on Keypad, and Also can be Transmited to Central Station

Spare Battery in Low Power

Expansion Module of Power Suplly Battery in Low Power

Siren Circuit in Trouble

Power Expansion Module of Siren Circuit in Trouble

Phone Line Failure

Loss of AC

Loss of Auxiliary Power

System Clock is Not Set

Line Communication is Blocked

Tamper Prevention

Fire Alarm Circuit in Trouble

 

Installation

All Expansion Modules can be Connected to the system by 4-Line

The Distance is Up to 1500M Between Module and Control Panel

 

Technical Data

Transformer 16.5VAC 40VA

Spare Battery 12V4AH or 12V7AH

Auxiliary Power Supply 400mA

Switch lock 250mA

Siren 750mA


Product Image
RP248CN 8-48 Zone Control Panel
Related Products
RK110W PIR Wireless,10M, 433MHz
RK110W PIR Wireless,10M, 433MHz
USD $ 11
RP208CN 8 Zones Main board + LCD Keypad +Metal Box + Transformer
RP208CN 8 Zones Main board + LCD Keypad +Metal Box + Transformer
USD $ 40
RK210PT	PIR Motion Detector with Pet Immunity,10M
RK210PT PIR Motion Detector with Pet Immunity,10M
USD $ 6
AT201R AT201R01 Remote Control Module
AT201R AT201R01 Remote Control Module
USD $ 4.5





Powered By DIYTrade.com Build your FREE website Find Made in China card Products !