| RP248CN 8-48 with popular LCD keypads, 8 programmable zones, and the features of network linking and alarm linkage output. It is compatible with internationally popular communication format. With chargeable circuits and clock. It has memory function, so that the programmed parameters and the information of the control panel's condition would not lose when power is cut. The function is perfect, the programming is convenient, the installation is easy, and the usage is safe. It supports programming any address information at will. It could greatly reduce the working time of installation and programming . RP248CN 8-48 adopts the latest technology, LSI Application, SMT jointing technology, and digital program design to ensure the reliability and stability of the system. Its appearance is compact and elegant with reasonable layout. The distance is up to 1500M between control panel and module.
LCD Keypads (RP248KCL)
Display of Two Lines and 32 Characters 3 Keypad Emergency Zones: Panic[1]+[2], Fire[4]+[5], Special Emergency[7]+[8] Menu Indicates the User Functions and the Installer Programing Key-press with Audible Feedback System Condition Display Trouble Display LED Indication: Alarm, Power, Armed, Disarmed, Bypass, Ready, Tamper User Information is Displayed on Screen (except for password) LCD Backlight Tamper is Supervised Alarm By Duress Code Easy to Use Hot-keys for Simple Bypassing and Not-ready Zones Display One Button for Quick Arming One Button for Quick Perimeter Arming Alarm Memory Display System Trouble Display Up to 4 LCD Keypads can be Connected Mainboard(RP248MB) Zone Terminal Resistor (2.2KΩ) 8 Zones on Mainboard Expandable up to 48 Programmable Wired Zones or 8 Wired Zones + 40 Wireless Zones Special Zones: Zone-5 is Fire Zone, Zone-6 is Tamper Zone Can be Parted to 8 Divisions 11 types of Programmable Zones, 7 Types of Voice Formats Zone Terminal: NC, NO, Single End with Resistor Programmable Output: 70mA Expandable to 32 Large Current Output: 3A 50 Event Records 8 Groups of 4 Gradable Codes Switch Output: 250mA Built-in Siren Driver: 750mA max Built-in Digital Clock Daily Test Report Function of End Calling Disarm/Arm Report 4 LCD Keypads can be Connected to Control Panel Programmble Voice For the Siren Output Current output:750mA(max) Auxiliary power Output: 400mA Mainboard has 7 types of Fire Alarm Bell Voice Driver Connectible with Four 1.5V 12A Power Supply Expansion Board Mainboard has One 70mA Programmable Open Circuit Collector Connectible with 32 C-type Programmble Relays of 3A Circuit Responding Time of Each Zone can be Set as 10ms, 500ms or 1s The Distance is Up to 1500M Between Module and Control Panel Built-in Digital Communicator Attached Digital Communicator, Compatible with Contract ID,4+2 2 Central Station Numbers 4 Follow-me Phone Numbers Code One Installer Code One (User) Main Code (Can Create Duress Code Automatically) 8 Gradable User Codes Periodic Test Offer Testing Report to Alarm Center Automatically Peripheral Equipment Expandable Function of 32 lines Relay Output Disarmed/Armed by Romote Control. Any Zone can be Programmed to be the Switch Lock Port RS232 Port Expandable Zone Board 8 Zones Expansion Module EZ8 8 Zones Wiring Expansion Module Power Supply Output of Switch Lock Zones Terminal: NC, NO, Single End with Resistor (2.2kΩ) Circuit Responding Time of Each Zone can be Set as 10ms, 500ms or 1s 4-Line Connection, and Easy for Installation 8 Zones Wireless Expansion Module EW8 Wireless Expansion Module Time to Supervise is Programmable Monitoring of Emitter in Low Power Tamper of Emitter is Supervised Indication of Interfering Signal Wireless Detector is Supported Verifying code by cycle 4 Program Output Expansion Module E04 4 lines programmable output(3A) Output: NC, NO, Locked or Pulse Responding to Various Events XTO Module Supports X-10 Agreement Power Supply Output Expansion Module (RP248EPS) Connect with 5 Modules by 4-Line Provide 2.0A,12V Power to Other Module and Siren Complete Supervision of Power Supply condition, including Battery, AC, Siren Circuit and Auxiliary Power Output Built-in Siren Driver Tamper is Supervised Memory When Power is cut Digital Voice Module RV2006V 1 Piece of Voice Message, Time Lasts 20s Follow-me Number is Assignable Timing Function Auto Daily Arm Auto Daily Test Report Disarm/Arm Report at Window Monitoring Function Trouble Data can be Displayed on Keypad, and Also can be Transmited to Central Station Spare Battery in Low Power Expansion Module of Power Suplly Battery in Low Power Siren Circuit in Trouble Power Expansion Module of Siren Circuit in Trouble Phone Line Failure Loss of AC Loss of Auxiliary Power System Clock is Not Set Line Communication is Blocked Tamper Prevention Fire Alarm Circuit in Trouble Installation All Expansion Modules can be Connected to the system by 4-Line The Distance is Up to 1500M Between Module and Control Panel Technical Data Transformer 16.5VAC 40VA Spare Battery 12V4AH or 12V7AH Auxiliary Power Supply 400mA Switch lock 250mA Siren 750mA
|